Are Fresh-Air Air Conditioners That Require No Larger Wall Opening Reliable?

2023-10-20 14:02:34

Click:

“ No-enlargement installation preserves the wall but restricts duct area. Achieving adequate fresh-air volume then requires higher air velocity, making it difficult to balance airflow and noise. ”
A fresh-air air conditioner needs a separate outdoor-air duct, while the wall opening reserved for an ordinary air conditioner is only about 6 cm in diameter. This creates an installation challenge: either enlarge the opening to at least 8 cm—wall-mounted fresh-air units often require more than 10 cm—or avoid enlarging it by using one sleeve to contain both the fresh-air duct and the refrigerant lines.
Both approaches appear to have advantages and disadvantages. Enlarging the opening is the obvious choice because the additional fresh-air duct needs enough space. A larger opening allows higher fresh-air volume and lower noise, although it can reduce the installation's visual appeal.

For this reason, many air-conditioning brands now offer installation solutions that require no larger opening. Their purpose is to keep the room looking attractive and avoid further damage to the wall. To some extent, this approach does meet users' needs.

However, avoiding enlargement inevitably reduces the cross-sectional area available for the fresh-air duct. A narrower duct delivers less air per unit of time. Maintaining adequate fresh-air volume therefore requires a higher air velocity, which in turn creates more noise.

China's national standard GB/T 18883-2002, Indoor Air Quality Standard, specifies that indoor fresh-air volume should be at least 30 m³/(h·person), or no less than 30 m³/h for each occupant. In a bedroom occupied by two people, for example, a fresh-air air conditioner installed without enlarging the opening should deliver at least 60 m³/h. A living room requires even more fresh air.

According to the Allowable Air Velocities for Different Noise Standards in Air-Conditioning Fresh-Air Ducts, a main-duct velocity of 9 m/s corresponds to a noise requirement of 45 dB, which is already far from quiet. If a wall-mounted unit uses the existing opening and allocates even half of its cross-sectional area to the fresh-air duct, the air must travel at 11 m/s to provide suitable fresh-air volume, making the noise still higher.

The actual user experience of a so-called no-enlargement fresh-air air conditioner may therefore fall short of expectations. Its principal drawback is the difficulty of balancing fresh-air volume with noise.
0
Are Fresh-Air Air Conditioners That Require No Larger Wall Opening Reliable?
No-enlargement installation preserves the wall but restricts duct area. Achieving adequate fresh-air volume then requires higher air velocity, making it difficult to balance airflow and noise.
Long by picture save/share

 

Company landline

010-60770969

Sales Phone/WeChat: 15601000090

Purchasing Management/WeChat: 13331060986

Company Phone: 010-60770969

Address: Room 1708, Building B, Jinyu International Center, Longyu East 1st Road, Huilongguan Street, Changping District, Beijing

©2026 Kelan Filtration Technology(Beijing) Group Co., Ltd. All rights reserved

Record Number: Jing ICP No. 2022016037-2

Technical Support: Suyuan Network

 

Sales Phone/WeChat: 15601000090

Purchasing Management/WeChat: 13331060986

Company Phone: 010-60770969

Address: Room 1708, Building B, Jinyu International Center, Longyu East 1st Road, Huilongguan Street, Changping District, Beijing

©2026 Copyright Beijing Kelan Fresh Air Technology Co., Ltd. All rights reserved

Record Number: Jing ICP No. 2022016037-2 

Technical Support: Suyuan Network

Service Center
Contacts
Product Sales :
15601000090
Procurement Management :
13331060986
Company Landline :
010-60770969
Qrcode
Qrcode
WeChat (scan to add)
Service Center
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.